Двухголовочный вакуумный шприцевой наполнитель
The HIJ-GZB200 combines two ceramic-pump filling paths with vacuum stoppering for prefilled glass syringes. Configure the machine around your formulation, syringe format and production layout.
Choose the format parts and auxiliary modules your project needs, then request an itemized equipment quotation.
Is GZB200 your fit?
Choose this double-head prefilled syringe vacuum filling machine for glass SCF syringe projects requiring both dosing and vacuum stoppering. Two ceramic plunger-pump paths, rising filling needles and paired stoppering tools form the core working sequence. Liquid and ointment projects are configured around their actual dosing and handling requirements.
The documented syringe formats are 0.5, 1, 2.25, 3, 5, 10 and 20 ml. These are separate format options, not one universal tooling set or a continuous dosing range. Barrel geometry, flange, nest pitch, stopper dimensions and the intended fill must be matched together.
Match the syringe, nest and stopper as one format set. The agreed component drawings and samples establish the handling parts and stoppering tooling supplied for your machine.

Создайте свою конфигурацию
Separate the core filling and stoppering process from the modules you want quoted. This gives your team a clear equipment scope before comparing prices.
- Основной процесс
- Two ceramic-plunger filling paths, rising needles, stopper feeding and vacuum stoppering tooling.
- Options to specify
- Automatic nest removal, a 15 L de-foaming vessel, local laminar-flow hood and rod-insertion equipment. Identify the selected format parts and options in the quotation.
Подберите путь дозирования
Review viscosity, temperature, foaming behavior, required dose and product-contact compatibility. The technical schedule separates ceramic valve selections for water-like and paste products; one assembly should not be assumed to cover every formulation.
A 15 L material de-foaming vessel is an optional upstream item. Select it when the product preparation and filling trial justify it, and define cleaning and connections with the rest of the product path.
Match the full component set
Review the syringe, stopper, nest presentation and dose together. A change of nominal ml size may also require handling parts, stoppering tools, another valve selection or program settings.
List the format sets actually included in the quotation and identify the change parts supplied with each. Where several formats matter commercially, include representative changeover and restart checks in the acceptance scope.
Define the module boundaries
Choose stand-alone operation or specify the transfer to other equipment. Available project options include an automatic nest remover, local laminar-flow hood and rotating-rod machine; additional rod detection is a separate selection.
Define ownership of conveyors, signals, guarding, utilities and stopped-machine behavior. The pictured enclosure does not by itself establish the environmental class or validate a sterile manufacturing process.

Fill, then stopper
The machine brings dosing and stoppering into one sequence, but they remain different functions. Looking at each stage makes the included automation clear and helps define the equipment interfaces.


- Prepare and feed
- The documented workflow begins with an operator manually peeling the nest-box sealing film. Syringe transfer follows the selected handling arrangement. Automatic nest removal is an additional module; it is not the same operation as automatic film peeling.
- Дозируйте наполнение
- Two ceramic plunger-pump paths deliver the selected dose. The filling needles rise with the liquid level. Pump/valve selection, needle movement and the filling program are matched to the formulation and syringe.
- Поместите пробку
- The stopper feed and paired tooling serve the vacuum stoppering operation. The filling settings and stoppering vacuum window are agreed separately, together with stopper position and the finished-syringe checks.
- Transfer onward
- The completed syringe moves to the selected discharge arrangement. Rod insertion and downstream packaging belong to separately defined modules and interfaces, rather than an assumed complete line.
Vacuum can support a particular filling or stoppering process, but a vacuum reading alone is not evidence of the final product result. Use a trial with the intended formulation and components to establish the operating window.
Технические детали
Use these documented values to start the equipment review. The quotation should identify the actual selected configuration; finished output and dosing results are confirmed against the agreed product, components and test method.
Заполнение и вывод
- Иглы для наполнения
- 2
- Reference production
- 800–1,200 шприцев в час
- Filling accuracy reference
- ±1–2%; define dose, measurement method and acceptance criteria
- Documented syringe formats
- 0.5 / 1 / 2.25 / 3 / 5 / 10 / 20 ml; format-specific configuration
Монтаж и коммунальные услуги
- Габариты основного станка
- 1020 × × 840 1730 мм
- Вес главного двигателя
- 400 кг
- Мощность
- 3 кВт
- Электроснабжение
- 380 V or 220 V; 50–60 Hz selection
- Сжатый воздух
- 0.55–0.75 MPa; 15 L/s source reference
- вакуум
- Confirm the selected system, connections and process operating window
Материалы и средства контроля
- Экстерьер
- 304 stainless steel reference
- материалы, контактирующие с продуктом
- 316L stainless steel and medical silicone reference; confirm product compatibility
- Архитектура управления
- PLC, HMI and servo-controlled operation
- График компонентов
- Identify the supplied brands and revisions in the final quotation; source brands can change
The footprint and weight above describe the main machine, not the entire arrangement with a nest-removal unit, hood or rod-insertion module. Allow for the selected auxiliary equipment, operator access, material staging and maintenance access in the layout.
Область допустимых отклонений
Turn the purchase specification into a short, testable acceptance schedule. The reference speed is useful for comparing equipment, but the buying decision needs evidence for the particular syringe and formulation.
View acceptance and handover details
- Product and component identity
- Record the formulation or agreed trial material, dose, syringe, stopper, nest presentation and drawing revisions used during the run.
- Dosing and stopper placement
- Agree sampling across both filling heads, the measurement method, allowed variation and the checks for stopper position and syringe condition.
- Полезный выход
- Measure accepted syringes over an agreed run duration. Record rejects, stops and replenishment so the result is not confused with a theoretical cycle rate.
- Эксплуатация и передача
- Name the required alarm, interlock, recipe and restart demonstrations, together with the documents, operator instruction and any selected changeover checks.
Agree which checks take place at the factory and which depend on the installed process. Equipment FAT and site/process qualification are related stages, not interchangeable evidence.
Вопросы покупателей
How are the two filling heads checked?
Include head-level sampling in the agreed dosing test so a combined average does not hide a difference between the two paths. State how samples are identified and measured, then review both the individual results and the overall run.
Does a hood establish aseptic operation?
No. A local hood is an equipment option, not proof of an aseptic process. The installed environment, components, material transfers, cleaning or sterilization approach, operation and qualification responsibilities must be addressed for the intended manufacturing process.
Can the formulation change later?
Review the affected dosing parts, seals, needle settings, product preparation and acceptance method before treating the original scope as unchanged. A different viscosity or foaming behavior may change the required trial and selected equipment even when the syringe size stays the same.
Сравните маршруты
Choose by the actual syringe process, not just by the number of filling heads.
Review the other vacuum filling and stoppering route.
Compare the DZA200 when the project uses the plastic-syringe arrangement.
Define the downstream packaging interface separately.
Clarify the supplied component presentation before choosing handling equipment.
Plan your GZB200
Send your existing URS, component drawing or project reference. We can use it as the starting point for a configuration discussion; add only the details not already covered there.
Ask for an itemized quotation identifying the machine, format parts, selected options and acceptance scope. Pricing is by configuration.
Запросить индивидуальное коммерческое предложение